spoiler

For people that don’t know this is not how you use Calipers

  • CADmonkey@lemmy.world
    link
    fedilink
    arrow-up
    52
    ·
    1 year ago

    I remember when I first applied for a job in a fabrication/machine shop. One of the questions in the interview was “Do you know how to read a tape measure‽” followed by “demonstrate that you can use a tape measure” along with some other fun ones like “what is the difference between these two pieces of material” (one was aluminum, the other stainless) and other such things. I remember being surprised/disappointed that there were grown people who couldn’t read a tape measure.

    I’ve worked in machine shops and drafting offices for years now, and I’m no longer surprised by people who can’t use basic measuring tools. Still disappointed though.

    • bitsplease@lemmy.ml
      link
      fedilink
      arrow-up
      10
      ·
      1 year ago

      OK - now I’m curious, what were the most common mistakes people made reading a tape measurer? Because I’m having trouble working out how someone could screw that up lol

      • CADmonkey@lemmy.world
        link
        fedilink
        arrow-up
        19
        ·
        1 year ago

        We had a guy we called “10/16” (ten sixteenths) because he was told to grab some 5/8" (0.625" or 16mm) steel plate, but he couldn’t find any he could only find 10/16" and 12/16".

        People will count the little lines on the tape and not remember if they are 1/32, 1/16, or 1/8.

        I think metric would help this.

        • bitsplease@lemmy.ml
          link
          fedilink
          arrow-up
          11
          ·
          1 year ago

          Oh OK - that does make a bit more sense. Still not exactly Nobel prize material, but fucking up the fractions at least makes more sense than not knowing how to read numbers and count lines lol

          Metric would help with everything lol. I dream of the day we finally make the switch

        • instamat@lemmy.world
          link
          fedilink
          English
          arrow-up
          6
          ·
          1 year ago

          Yeah, fractions are dumb. Or I’m dumb and fractions are easy, but why don’t we split the difference and switch to metric?

        • Peppycito@sh.itjust.works
          link
          fedilink
          arrow-up
          3
          ·
          1 year ago

          I worked with a girl who would say “4 and 3 ticks!” meaning 1/8ths. We laughed at her enough that she tried to improve and started saying “4 point 3!” that lead to a discussion about decimal inches. I really blew her mind when I showed her the scale in 12ths on carpenter squares.

        • nslatz@lemmy.world
          link
          fedilink
          arrow-up
          2
          ·
          1 year ago

          I worked on a site with two carpenters once, and one would measure and the other cut. One guy would call out “inch and a quarter strong” or " inch and a quarter weak" etc. Meaning 1 inch and 3/8 or one inch and 1/8. Perfect cuts every time.

          • Croquette@sh.itjust.works
            link
            fedilink
            arrow-up
            1
            ·
            1 year ago

            Isn’t strong or weak mean where the cut needs to be on the line? Since the blade is usually 1/8", weak means that the cut is made before the line, removing the thickness of the blade on the measurement (1 1/2" becomes 1 3/8") and strong means that the cut is made after the line, leaving the actual measurement. This is how I was thought, but I am not in the construction industry.

            • Peppycito@sh.itjust.works
              link
              fedilink
              arrow-up
              2
              ·
              1 year ago

              Depends on the crews tolerances? I’ve used + or - to refer to 16ths and only call out 1/8ths. 1 1/2" would be “One and four” 1 7/16ths would be “One and three plus”

              In old timey boat building they denoted feet°inches°eighths°plus so 58 5/16ths would get written as 4°10°2+

        • scarabic@lemmy.world
          link
          fedilink
          English
          arrow-up
          10
          arrow-down
          1
          ·
          1 year ago

          Or they even say this is a sign of wear and means you should throw it out.

          And because I enjoy sharing knowledge more than boasting I know more than others: the reason it moves is to account for the thickness of the metal hook itself.

          It makes a difference if you are hooking it onto the back of something and measuring from there, OR butting it up onto something and measuring from there.

          If you want accurate and consistent readings in both of these situations, the hook has to move. It basically pivots around the true point you’re measuring from.

          • CADmonkey@lemmy.world
            link
            fedilink
            arrow-up
            2
            ·
            1 year ago

            Everywhere I’ve worked, you’d “burn an inch” or “burn a foot” meaning you don’t use the metal tab, you hold the 1" or 1’ mark at the start and measure from there.

    • grue@lemmy.ml
      link
      fedilink
      arrow-up
      6
      ·
      1 year ago

      “what is the difference between these two pieces of material” (one was aluminum, the other stainless)

      Did they expect you to identify which metals they were, or just that they were different metals?

      • CADmonkey@lemmy.world
        link
        fedilink
        arrow-up
        8
        ·
        1 year ago

        I was expected to know that one was stainless steel and the other was aluminum, but not the specific grades of stainless or aluminum. Stainless and aluminum can look very similar when they’re dirty, and 300 series stainless won’t stick to a magnet just like aluminum won’t stick to a magnet. But if you pick them up or even rap on them with your knuckles you can tell the difference.

    • sp00nix@lemmy.ml
      link
      fedilink
      arrow-up
      4
      ·
      1 year ago

      After having a customer chew us out for something that wasn’t our fault he had us follow him to another room to discuss some more work. He borrows my tape measure and tries to measure something on the wall and the tape keeps falling over and flexing. It finally hits him in the face and hands it back to me and says “I’m not familiar with this type of tool”. I think he saw our faces turn red and eyes water up as we were trying SOOO hard not to laugh.

  • Machinist@lemmy.world
    link
    fedilink
    English
    arrow-up
    41
    ·
    1 year ago

    Oh jeebus fucking christ. Sometimes the dumb hurts and then you get the existential dread knowing you’re about to have to call this moron. And, even better, they usually make more money than you.

  • knorke3@lemm.ee
    link
    fedilink
    arrow-up
    29
    ·
    1 year ago

    please close and reverse the tool, then grip it tightly and drive it into the skull of the complaining customer

  • Dubious_Fart@lemmy.ml
    link
    fedilink
    English
    arrow-up
    19
    ·
    1 year ago

    I am a certified blithering idiot and even I feel like a high society intellectual compared to this picture.

  • pigup@lemmy.world
    link
    fedilink
    arrow-up
    14
    ·
    1 year ago

    They were trying to design a caliper holder that fits the jaws in that orientation, obviously. They need to fix this, send it back.

  • HonoraryMancunian@lemmy.world
    link
    fedilink
    arrow-up
    8
    arrow-down
    20
    ·
    1 year ago

    This just tells me calipers should have 2 measuring bars on them, so gaps and other inside edges can be measured like this (maybe this already exists, idak)

    • flubba86@lemmy.world
      link
      fedilink
      arrow-up
      46
      ·
      1 year ago

      That’s what the two prongs at the top are for. Flip the caliper upside down, use the prongs to measure the inside dimension, and read it off the same scale.

        • rz2000@lemmy.world
          link
          fedilink
          English
          arrow-up
          13
          arrow-down
          2
          ·
          1 year ago

          “Caliper jaws for inside measurement—I thought of that. Turned out it already existed, but I arrived at it independently."

          • flubba86@lemmy.world
            link
            fedilink
            arrow-up
            3
            ·
            edit-2
            1 year ago

            I think the guy was actually referring to something a bit different, that is having a second number scale on the caliper that is offset by the width of the first jaw, so you can use the outside jaws for measuring inside dimensions. I don’t think that would work, however.

            • HonoraryMancunian@lemmy.world
              link
              fedilink
              arrow-up
              4
              arrow-down
              2
              ·
              edit-2
              1 year ago

              I was indeed (and I think you’re right, the calipers would need at least to be parallel on their outer edges to work this way).

              I’m not sure what rz2000 was doing by (slightly wrongly) rewording basically what I wrote — I get the impression they think I was being full of myself for thinking of a (similar) concept that already exists (despite conceding that it already might) and felt the need to put me back in place.

            • brianorca@lemmy.world
              link
              fedilink
              arrow-up
              1
              ·
              1 year ago

              By using the same scale for inside and outside, you can take one measurement inside, and compare it to something else as outside without moving the scale at all.