Title reads like at ad, but this is a new way to reach energy independence. I actually have a small EcoFlow device and it’s pretty good for the price.
I hope this tech can be made available in the US soon.
Plug-in systems are built around a microinverter that feeds solar energy back into the home via a standard wall jack.
What the actual fuck?
The PowerStream has three proprietary ports: one that connects to your MC4 solar panels
Disqualified.
First part is classic stuff right?
I’m also against proprietary systems but is there an open alternative?
Plug-in systems are built around a microinverter that feeds solar energy back into the home via a standard wall jack.
What the actual fuck?
What’s wrong with that? That’s how basically any balcony solar system works.
The cables in your walls are designed for a certain maximum current before they start to heat up. This current is limited by your breaker.
Now if you introduce a plug in solar setup your current is limited by your maximum breaker capacity + whatever your solar setup can generate.
So if I’d use the specs from the article and apply it to a normal dutch home situation: 16A breaker, + 800W at 230V, which means ~3.5A = 19.5A max. which is probably still fine for short durations.
But now some genius doesn’t read the fine print and hooks up 2 or 3 on the same circuit. There is no electrician that tells him that’s dangerous because it’s all self installed and he doesn’t know any better. And all of a sudden you are up to 26.5A and you got glowing, smoking wires in your walls…
Your breaker will pop. Just like if you were to run a hair dryer on each outlet.
The breaker only sees the current flowing through the breaker though. Not the additional current provided by the solar panels since those don’t flow through the breaker. So it will pop later then that the cables are rated for, therefore introducing an overheat and fire hazard.
Maybe for a same-circuit device that’s consuming more than the breaker can provide? I don’t know enough about this tech but would expect this can be accounted for in some way.
There are ways to somewhat fix it for circuits with a single use.
Fixing the same example: A 16A breaker for the solar feed in, a single 16A breaker for all the consuming appliances on that circuit. And another 16A breaker on the feed in for that circuit is an example that is sometimes used in the Netherlands to add a feed in to an existing circuit with a single outlet connected to it. Meant for washingmachines for instance.
This ensures that the circuit on all circumstances has a maximum current of 16A flowing over any wire by also measuring the outgoing current of both feed in circuits. But if you have multiple outlets you’d still need to stiol measure at a single place or use low enough breakers per outlet that the total stays below the 16A. Which the UK might have if I recall correctly.
Then again this is not a normal setup and requires change in the electric circuit of the home. Which most consumers won’t even realize. Like I said, if everyone keeps to the fine print this thing probably has and limits the extra plug-in solar panels to 1 per circuit, it’s unlikely to actually cause issues because of overdimensioning of the wires. And the safety margin built in which is likely how they have gotten approval. But ignoring or not reading that text and plugging multiple in on the same circuit can and will cause a fire hazard with heavy consumers on the same circuit.
Also, emergency service hazard. The PV won’t turn off if firefighters take out the mains, which makes a house potentially inaccessible during an emergency.
Surprisingly, no. Most inverters in the EU must come with island protection. Meaning that if there is no AC from the grid it immediatly switches off the inverter or the battery, there is no stand alone operation.
There are some systems that allow it but they are rare here and require the mains side to be fed trough the inverter itsself ensuring it’s never back feeding into the grid when there is no power with the same island protection, or less commonly there is a transfer switch of some kind also eliminating the issue. And either should obviously have a main kill switch on the breaker board for emergencies that also switches off the in home power with 1 action.
But most importantly, either of those options is not plug and play and will require an electrician that hopefully does know what he’s doing.
Does the island protection with if you have two inverters running independently? (legally or not)
Yep, I’m not exactly sure on the technical details but it works with multiple inverters. Otherwise having a street full with solar panels on every roof would still be a hazard if the power went out at a distribution junction for said street and repairs would have to be made.
If there is no powerplant feeding some energy, all inverters should shut off. Fixed installs and plug and play variants alike. I’m actually amazed that there are parts in the world where this isn’t common.
I looked into these before and believe the inverters shut off if the mains shuts off. The DC side of the circuit would still be potentially dangerous though.
The inverters need there to be power in the mains circuit because they convert DC to AC and match the phase of the AC power they are generating to the mains supply.
But now some genius doesn’t read the fine print and hooks up 2 or 3 on the same circuit. There is no electrician that tells him that’s dangerous because it’s all self installed and he doesn’t know any better. And all of a sudden you are up to 26.5A and you got glowing, smoking wires in your walls…
Ok sure, that makes sense. This might actually be an issue.
I would, but i’m not allowed by the HOA the hang shit on my balcony.
Fuck’n HOA assholes.
My balcony is also on the right side of the building too, it would be perfect.
Vote.
I ran my small HOA for 1 term and people came at me, bitched about stuff and I got them to come to a meeting where the other homeowners could express their concerns about the proposal and we’d come to an agreement and write up a change. It was no big deal. We even negotiated group rates for shared services and made it so that the costs of the HOA were offset by the savings from the services.
On the other side of the coin, when I left my position to give somebody else a turn at the process I largely automated, they ran it into the ground and bankrupted it while chasing a personal grievance against the city.
Somehow, the HOA attracts power hungry nobodies but they can be voted out if you’re willing to work at it. Also, talk to your neighbors. My guess is that there are others who would back your proposal.
I can’t really find any info regarding renters when it comes to these hoa things or being allowed to partake in a meeting, but i would assume they could care less about a renters opinion unless it benefits them.
I can’t afford to be a homeowner.
I’m sorry to hear that. I remember renting and the feeling of having no control over the whims of the landlord.
HOAholes
Worst Santa.
Wow that’s interesting. I hate how much power my pool eats up in the summer, I’ve been looking for something economical to help run it off of clean energy since the pump runs during peak solar hours anyway.
You can do that today with their setup I think. You would need to plug the pump into one of their batteries and run their solar panel to the battery. You’d also put the battery on grid power.
The article is focused on an inverter that pushes energy back to the grid, something we don’t have yet at this market level.
Just get solar then. Seems like the solution you are looking for, no?
Yeah, but between federal and state credits, different types of systems, etc. I’ve had a hard time determining what makes the most sense for me. Doesn’t help that trying to do online research quickly funnels you into sales bs.
Most European residential electric systems operate at 240v, versus 120v in the US, which means you can only backfeed a US outlet with half the power you could in a European outlet. That alone makes this system half as useful for US applications.
If one of these were made for the US market it would obviously be configured to work at the US mains voltage and frequency. (Europe is 50hz, US is 60).
Your home’s power input is also 240 volts in the US, regardless of being split into two 120 volt rails at the breaker box. It would be trivial to hook up a 240 volt system if you really wanted to, albeit not through one of your regular 5-15/5-20 outlets. You’d have to do it via a dryer outlet or something.
Watts are watts. If the unit is capable of feeding 800 watts into your home’s electrical system, the voltage is irrelevant provided it can supply sufficient amps. A normal US household circuit is 15 amps, so a hypothetical US version of this thing would have to supply ~6-2/3 amps at 120v rather than ~3-1/3 amps at 240v. No big deal. It’s not even close to maxing out a single residential circuit on either continent.
Just to expand, here’s a list of typical 240V appliances in a typical American home:
- Furnace/Heat Pump
- Air Conditioning
- Electric Range/Stove
- Electric clothes Dryer
And some homes have:
- Hot Tub/Spa
Don’t conflate 120V/15A standard outlets with not having 240V at all. All homes have 240V or high power appliances wouldn’t function.
I have a couple in my garage because the previous owner liked carpentry, and I’ll use it when I get an EV.
That’s not that uncommon.
Your home’s power input is also 240 volts in the US
It’s not actually 230V in Europe, it’s 400V. Between each pair of the three phases, that is, between phase and neutral there’s 230V. (If there’s a neutral and you don’t create it locally, different topic).
…but I’d actually have different doubts about using the whole thing in the US: Your plugs. Schukos aren’t meant for the purpose and only code for up to 800W when used to backfeed. That’s almost 1/5th of their 1 hour continuous rating. With those flimsy tinfoil plugs you have you’re going to need special outlets, or hard-wire them.